Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The outbox poller serves two purposes. The first is to process messages from the outbox that do not contain a case ID because they are sent from the process engine. Currently, this only contains process finished messages. The default interval for this poller is 1 minute. The second is to process messages from the outbox that have failed to be sent initially and would otherwise remain in the outbox forever. This outbox poller reads from the outbox table on startup and every 30 minutes by default. 

...

Starting from version 16.7, the property blueriq.case.engine.outbox.poller.interval.minutes can be used to update the interval. The value is of type Duration and default value is 2M. See Duration for the different value options.

Code Block
languagetext
titleExample
blueriq.case.engine.outbox.poller.interval.minutes=15m # default is 30m

Starting from version 17.4 it's also possible to set a separate interval for messages coming from the process engine, which don't contain a case ID.

Code Block
languagetext
titleExample
blueriq.case.engine.outbox.poller.process.messages.interval.minutes=60s30s # default is 1m

Batch size

Starting from version 17.2, the property blueriq.case.engine.outbox.poller.batchsize can be used to set number of messages that are retrieved from outbox table. The default value is set to 10000.

Code Block
titleExample
blueriq.case.engine.outbox.poller.batchsize=50000

Async processors

Starting from version 17.2, the property blueriq.case.engine.outbox.async.threads.pool.size can be used to set number of threads that process messages retrieved from the outbox. The default value is set to 1.

Code Block
titleExample
blueriq.case.engine.outbox.async.threads.pool.size=5

Outbox Tuning

Additional information about tuning and configuring Outbox can be found here - Best practice - How to tune the Case Engine components.