Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The BMA allows to configure its rules according to modelling conventions that have been made at your project. To do so, follow these steps:

...

  1. Changing the parameters of rules requires logging in. The default SonarQube credentials are "admin", "admin". 
  2. After choosing the tab "Quality Profiles", the built in Blueriq Rules Profile should appear in the list.
    1. From SonarQube version 6.7, it is no longer possible to manually change built in profiles. Therefore we suggest you make your own copy of the Blueriq rules

...

Blueriq language

All Blueriq specific rules can be viewed in an overview through the Rules tab, optionally by filtering on Language Blueriq at the right of the screen:

Image Removed

    1. profile and make this the default one.
  1. By clicking on one of the active rules, for instance the parameterized "Decision table gap/overlap analysis" rule, a detailed overview of the specific rule is presented.
  2. When clicking on the change button, the parameters are presented and editable.
  3. Rules can also be deactivated by clicking the deactivate button at the right hand side of the overview.
  4. After changing the parameters, you have to run a new analysis in order to see the effect of the changes. 

Image Added 

Parameters in rules

Some of the Blueriq specific rules take in parameters during analysis. These parameterized rules use default values, but if needed these default values can be overridden through Sonarqube's web interface. The parameterized rules are:

...

Rule

Explanation

Elements in flowBy default the elements in flow rule has maximum elements value of twenty. By settings this property the maximum value can be increased or decreased.
Flow viewportBy default the flow view-port rule checks if the flow does not exceeds the boundaries of the default view-port which is x=1700,y800. By settings these properties the view-port can be made smaller of bigger.
Expression SimplifierBy default the expression simplifier rule uses boolean logic to check if expressions can be simplified. By setting this property to false the rule will use three valued logic instead.
Metadata in aggregateBy default the number of metadata fields in an aggregate is set to 10. By setting this property the number of fields can be increased or decreased. Increasing this number is discouraged as it can affect the performance of the application
.

Changing parameters 

.

...

Image Removed

By clicking on one of the active rules, for instance the parameterized "Elements in flow" rule, a detailed overview of the specific rule is presented:

Image Removed

When clicking on the change button on the right, the parameters are presented and editable:

Image Removed

Deactivating rules

After logging in, rules can be deactivated by clicking the deactivate button at the right hand side of the overview.

...